Fire safety, licensing and the 2025 Act

Venue capacity calculator: what is my venue's capacity?

No single legal formula sets a venue capacity in England and Wales.

Question 1

What states a capacity figure for your venue today?

Pick the strongest evidence you actually hold. A number in a manager's head is not evidence.

Leave your email and we'll get straight back to you.

  1. We email you the questions a firm needs answered, straight away.
  2. You answer them by reply, or on this site.
  3. Up to three firms get your request.

Floor space factors used to calculate occupant capacity

Last updated

With no designed occupancy figure, Approved Document B volume 2 divides the room or storey area by a floor space factor. These are Table D1's factors, worked for 200 m². As a maximum occupancy calculator: divide by the factor, round down. The Office row is an office space per person calculator: 6.0 m² per person, so 200 m² holds 33.

Floor space factors used to calculate occupant capacity
Type of accommodationFloor space factor (m² per person)People in 200 m²
Standing spectator areas, bar areas within 2m of a serving point, similar refreshment areas0.3666
Amusement arcade, assembly hall, bingo hall, club, crush hall, dance floor or hall, venue for pop concerts, bar areas without fixed seating0.5400
Concourse or queuing area0.7285
Committee, common, conference, dining, meeting, reading or waiting room, lounge or bar other than above, restaurant, staff room1.0200
Exhibition hall or studio (film, radio, television, recording)1.5133
Skating rink, or shop sales area2.0100
Art gallery, dormitory, factory production area, museum or workshop5.040
Office6.033
Kitchen or library, or bulky-goods shop sales area7.028
  • There is no single national formula for venue capacity in England and Wales: Approved Document B sets an occupant number for fire safety, the Licensing Act 2003 allows a capacity condition on a premises licence, and the Terrorism (Protection of Premises) Act 2025 asks for a reasonable, evidenced expectation of numbers present.
  • Table D1 of Approved Document B volume 2 gives a floor space factor of 0.3 m² per person for standing spectator and bar areas within 2m of a serving point, 0.5 m² for dance floors and general assembly halls, and 1.0 m² for restaurants and meeting rooms.
  • Capacity figures used for the Terrorism (Protection of Premises) Act 2025 must include everyone working at the premises, whether employees, contractors or volunteers, not just members of the public.
How this was compiled, and how to cite it

Reproduced from Table D1 of Approved Document B (fire safety) volume 2, Buildings other than dwellings, published by the Ministry of Housing, Communities and Local Government on gov.uk, as at the updated date above. Paragraph D1 gives two methods for the occupant number: the maximum number of people the space is designed to hold, or area divided by a floor space factor. Paragraph D2 says counters and display units are included in the measured area, while stair enclosures, lifts, sanitary accommodation and other fixed parts of the building structure are excluded. The right-hand column is 200 square metres divided by the factor, rounded down. Approved Document B is guidance on meeting the Building Regulations, not a licensing or counter-terrorism standard: the figure it produces is a starting point that then has to be reconciled with your fire risk assessment and any licence conditions.

Cite this page

“Floor space factors used to calculate occupant capacity”, Venue Capacity Check, https://venuecapacitycheck.co.uk/ (updated 2026-08-14). Reproduced from Table D1 of Approved Document B (fire safety) volume 2, Buildings other than dwellings, published by the Ministry of Housing, Communities and Local Government on gov.uk, as at the updated date above. Paragraph D1 gives two methods for the occupant number: the maximum number of people the space is designed to hold, or area divided by a floor space factor. Paragraph D2 says counters and display units are included in the measured area, while stair enclosures, lifts, sanitary accommodation and other fixed parts of the building structure are excluded. The right-hand column is 200 square metres divided by the factor, rounded down. Approved Document B is guidance on meeting the Building Regulations, not a licensing or counter-terrorism standard: the figure it produces is a starting point that then has to be reconciled with your fire risk assessment and any licence conditions.

Need your venue's capacity assessed and documented?

We'll pass your details to up to three event and venue safety consultants, who contact you directly.

Next: where to reach you.

  • Free, no obligation
  • Your details go to at most three consultants
  • No marketing lists, ever

What this checker covers

  • Where a legally usable capacity figure actually comes from
  • Safe occupancy for fire safety, using the floor space factors in Approved Document B
  • Capacity conditions attached to a premises licence under the Licensing Act 2003
  • Whether staff, volunteers and contractors count (they do)
  • The 200 and 800 thresholds in the Terrorism (Protection of Premises) Act 2025, and the premises that stay standard tier whatever their numbers
  • Premises and events that sit outside the 2025 Act entirely

Venue Capacity Check is an information site. It is not affiliated with any government department, fire and rescue authority, licensing authority or the Security Industry Authority, and nothing here is legal advice. Capacity figures depend on the specific layout, use and exit provision of your premises: confirm yours with a competent fire risk assessor and your licensing authority before relying on it.

Frequently asked

Is there a legal formula for venue capacity in the UK?

No single one. Approved Document B volume 2 sets an occupant number for fire safety: the space's design figure, or the area divided by a Table D1 floor space factor. The Licensing Act 2003 has no formula and works through conditions. The Terrorism (Protection of Premises) Act 2025 asks for a reasonable, evidenced expectation of numbers present.

How many people per square metre can a venue hold?

By type of space. Table D1 of Approved Document B volume 2 gives 0.3 m² per person for standing spectator and bar areas within 2m of a serving point. It gives 0.5 m² for dance floors and general assembly halls, and 1.0 m² for restaurants and meeting rooms. Shop sales areas get 2.0 m² and offices 6.0 m².

How do I use this as a maximum occupancy calculator in the UK?

Measure the room or storey in m², divide by its use's Table D1 factor (Approved Document B volume 2) and round down. A 200 m² dance floor at 0.5 m² per person gives 400; as a restaurant at 1.0 m², 200. That fire occupant number must still fit your escape routes, fire risk assessment and any licence capacity condition.

Is a fire occupancy figure the same as a room capacity calculation?

A starting point only. Area divided by floor space factor gives the fire occupancy figure, but exits cap it. Approved Document B volume 2 needs one escape route up to 60 people, two up to 600 and three above. Exit widths and travel distances can lower it. Capacity is the lowest of the floor space, escape and licence figures.

Do volunteers count in venue capacity?

Yes, for the Terrorism (Protection of Premises) Act 2025. The Home Office guidance defines staff as all those working at the premises or event, whether employees, contractors, volunteers or otherwise, and they must be included in the assessment figure.

Does an outdoor venue have a capacity under the 2025 Act?

Qualifying premises must consist of a building, or a building and other land, so a purely open-air site is not qualifying premises. Parks, gardens, recreation grounds and other open-air leisure premises with free public access are also expressly excluded. A ticketed event held on open land can still be a qualifying event at 800 or more.

What happens if my capacity figure is wrong?

Under the 2025 Act the Security Industry Authority can require the responsible person to show how the assessment was carried out, using the information gathering powers in Schedule 3. Under fire safety law an occupancy figure that outruns the escape provision is a serious finding. Under licensing, exceeding a capacity condition is a licence breach.

Sources

This site's own dataset, every figure quoted from its source and dated:

  • The Occupancy Factor Table carries 1 published figure read from 1 source's own page, from 2.50 to 2.50 minute, read 7 November 2026.
  1. Approved Document B (fire safety), volumes 1 and 2
  2. gov.uk, fire safety in the workplace: your responsibilities
  3. Regulatory Reform (Fire Safety) Order 2005
  4. Licensing Act 2003, and gov.uk premises licence guidance
  5. Terrorism (Protection of Premises) Act 2025
  6. Home Office supplementary document A: methods for assessing numbers present

Know your number before someone asks for it.

Four questions gives you the tier. A documented figure gives you the answer to the regulator.

Embed it

Embed it anywhere; attribution stays on. Copy this:

<script src="https://venuecapacitycheck.co.uk/embed.js" async></script>
Talk to a specialist