How to calculate venue capacity: the five accepted methods

Updated

There is no formula you can apply blind. There are five recognised methods, and the right one depends on what your venue actually has: a fire strategy, a turnstile, a seating plan or a licence.

The five methods

The Home Office published a non-statutory supplementary document alongside the Terrorism (Protection of Premises) Act 2025 guidance setting out methods for assessing the number of individuals expected to be present. It is the clearest official list of the accepted approaches, and it is useful well beyond that Act (gov.uk).

A. Safe occupancy for fire safety
The maximum number that can reasonably be accommodated for fire safety purposes. Many venues already hold this figure from their fire strategy or fire risk assessment.
B. Historic attendance data
Records of actual numbers at peak times. The document warns that historic data is not always a reliable predictor and must be reviewed regularly.
C. Fixed seating or fixed standing positions
Count the seats or standing positions. Its worked example: 450 fixed seats plus 30 staff on duty gives 480.
D. Tickets and pre-registration
The maximum number of tickets that can be issued sets an upper limit. Its worked example: 300 presale plus 600 general sale plus 300 staff equals 1,200.
E. Restrictions
A maximum attendance or capacity figure attached to an alcohol and entertainment licence can be used directly. Its worked example: a nightclub licensed for 975, plus staff on duty.

A sixth option exists: other means, used with a written justification of why the alternative is appropriate, how the figure was calculated and why it is reasonable.

Staff always get added

The most common error is counting the public only. Where the method chosen does not already include staff, for example ticketing data or fixed seating counts, the staff number has to be added to reach the final figure. Staff means everyone working at the premises, whether employees, contractors or volunteers, full time, part time or shift workers.

The fire safety route in detail

Approved Document B volume 2 gives two ways to fix an occupant number: the maximum the space is designed to hold, or the area of a room or storey divided by a floor space factor from Table D1 (gov.uk). Measure the area including counters and display units, and exclude stair enclosures, lifts, sanitary accommodation and other fixed parts of the building structure. Where a space has more than one type of use, the more onerous factor applies. The factor table on the home page reproduces the full list.

Dwell time changes the answer

Total visitors in a day is not capacity. The Home Office document works an example: a stately home whose records show 850 visitors on a single day, but which assesses hourly counts and average dwell time and concludes the true maximum present at one time is 300. If your venue sells day tickets and people come and go, this calculation is the difference between two tiers.

Whatever method you use, write down which one and why. The regulator can require the responsible person to show how the assessment was carried out.

Questions, answered directly

How do you work out how many people a venue can hold?

Either use the number it was designed to hold, or divide the usable floor area in square metres by the appropriate floor space factor from Table D1 of Approved Document B volume 2. For a dance floor or general assembly hall the factor is 0.5 m² per person, so a 200 m² hall gives 400 people. Then add staff and reconcile with any licence condition.

Do staff count towards venue capacity?

Yes. For the Terrorism (Protection of Premises) Act 2025 the figure must include everyone working at the premises, whether employees, contractors or volunteers. Where your chosen method counts only the public, such as ticket sales or fixed seats, staff have to be added on top.

Know your number before someone asks for it.

Four questions gives you the tier. A documented figure gives you the answer to the regulator.