Calculator
Office space per person calculator: the two UK tests
Updated
Two official numbers decide office capacity. Fire guidance allows 6.0 m² of floor per person; workplace guidance asks for at least 11 cubic metres of room. The calculator gives both.
Talk to a specialist Four questions gives you the tier. A documented figure gives you the answer to the regulator.
Email me this result
We will send you these figures and a link back to them. One email, nothing else unless you tick the box.
How this calculator works
- The fire figure divides the floor area by the floor space factor for an office, 6.0 m² per person, from Table D1 of Approved Document B volume 2 (gov.uk). Counters and display units count in the area; stairs, lifts, toilets and other fixed structure do not.
- The workplace figure divides the room's volume by 11 cubic metres per person, counting any part of the room over 3.0 m high as 3.0 m (HSE, INDG244). HSE says 11 cubic metres is a minimum and may not be enough, depending on layout, contents and the work.
- Neither figure counts visitors to a meeting room or a reception differently: a room used for meetings takes the 1.0 m² meeting room factor for fire safety, so measure and calculate it on its own.
How much office space per person in the UK
For fire safety, Approved Document B volume 2 gives an office a floor space factor of 6.0 m² per person (Table D1, gov.uk). Divide the floor area by 6.0 and round down: 200 m² gives 33 people. That number sizes escape routes and exits, and it is the starting point a fire risk assessment works from.
For the people who work there, the Workplace (Health, Safety and Welfare) Regulations 1992 ask for enough free space. HSE's guidance sets the number: the empty room's volume divided by the people normally working in it should be at least 11 cubic metres (HSE, INDG244).
With a 2.4 m ceiling that is about 4.6 m² of floor each. A ceiling of 3.0 m or more brings it to 3.7 m², because height above 3.0 m does not count.
Office space requirements calculator: which number binds
At any ordinary ceiling height the fire figure is the lower of the two, so it is the one to plan to. The 11 cubic metre test would only ask for more than 6.0 m² of floor a person under a ceiling lower than about 1.83 m.
The workplace minimum matters differently, as the line a dense desk layout must never cross. The calculator above gives both and takes the lower.
| Ceiling height | Fire safety (6.0 m² each) | Workplace minimum (11 m³ each) | Holds on both tests |
|---|---|---|---|
| 2.2 m | 33 | 40 | 33 |
| 2.4 m | 33 | 43 | 33 |
| 2.7 m | 33 | 49 | 33 |
| 3.0 m or higher | 33 | 54 | 33 |
What the calculator does not tell you
- Desks and walkways. Both tests are minimums for the room. Furniture, storage and circulation decide how many desks really fit, and HSE says 11 cubic metres may be insufficient for the layout and the work.
- Escape routes. The occupant number feeds escape route widths and the count of exits: more than 60 people in a room or storey needs at least two exits. See what your capacity figure triggers.
- Mixed use. Where part of the floor is a meeting room, canteen or reception, each takes its own factor, and where uses overlap the more onerous factor applies. How to calculate capacity sets out the method.
These are the figures in published guidance, not a fire risk assessment. The responsible person still has to assess the premises as used.